CO2+Air Quality Duct Transmitter
Real time probe detect carbon dioxide and air quality (VOC)
of an air duct
Up to 3xanalog linear outputs
Modbus RS485
Monitoring parameters | CO2 | Air Quality (VOC) | Temperature | Relative humidity | ||||
Sensing element | Non-Dispersive Infrared Detector (NDIR) | Semiconductor mix gases sensor | Digital combined temperature and humidity sensor | |||||
Measuring range | 0~2000ppm(default) 0~5000ppm (selectable in the order) | 0~30ppm | -20~60°C | 0~100%RH | ||||
Display Resolution | 1ppm | 5ppm | 0.1°C | 0.1%RH | ||||
Accuracy@25°C(77°F) | ±40ppm + 3% of reading | ±10% | ±0.5°C | ±3%RH | ||||
Life time | 15 years (normal) | 5~7 years | 10 years | |||||
Calibration cycle | ABC Logic Self Calibration | —— | —— | —— | ||||
Response Time | <2 minutes for 90% change | <1 minute (for 10ppm hydrogen, 30ppm ethanol) <5 minute (for a cigarette) in 20m2 room | <10 seconds to reach 63% | |||||
Warm up time | 2 hours (first time) 2 minutes (operation) | |||||||
Electrical Characteristics | ||||||||
Power supply | 24VAC/VDC |
| ||||||
Consumption | 3.5 W max. ; 2.5 W avg. |
| ||||||
Outputs | Two or three analog outputs 0~10VAC or 4~20mA selectable by jumpers |
| ||||||
Modbus RS485 interface (optional) | RS-485 with Modbus protocol, 19200bps rate, 15KV antistatic protection, independent base address |
| ||||||
Conditions of Using and Installation |
| |||||||
Operation conditions | -10~50°C(14~122°F); 0~95%RH, non condensing |
| ||||||
Storage conditions | -40~70°C(-40~158°F)/ 5~95%RH |
| ||||||
Weight | 320g |
| ||||||
Installation | Fixed on the air duct with 100mm installation hole size |
| ||||||
IP class of the housing | PC/ABS IP54 for without LCD models; IP40 for with LCD models |
| ||||||
Standard | CE-Approval |
|
1.Designed for real time detecting carbon dioxide, air quality, temperature or relative humidity in air ducts.
2.NDIR infrared CO2 sensor inside with special Self Calibration and up to 15 years’ lifetime. It makes CO2 measurement more accurate and reliable.
3.Mix gases sensor with high sensitivity for VOCs results from new furnishings, wall coverings, office equipment, body odor, tobacco smoke, etc.
4.Combined temperature and humidity digital sensor provide a high accuracy in full range.
5.Provide up to 3 analog outputs (0~10VDC or 4~20mA) for CO2, air quality (VOC) and temperature or relative humidity.
6.Optional Modbus RS485 communication interface.
7.With LCD or without LCD selectable
8.LCD display real-time measurements of CO2, air quality (VOC), temperature and relative humidity.
9.Simple and smart design and installation of sensor probe with a water-proof and ventilated filter
10.Extendable probe meets more air duct systems
11.24VAC/VDC power supply.
12.EU standard and CE-approval.