Tongdy Control Technology Co., Ltd.

Ozone gas monitor/alarm

Ozone gas monitor/alarm
Product Detailed

Wall mount with LCD display
Electrochemical ozone sensor
two stage alarm
dry contact or analog output

 

Gas Detected

Ozone

Sensing Element

Electrochemical gas sensor

Sensor lifetime

>2 years, removable

Temperature Sensor

NTC 5K

Humidity Sensor

HS series capacitive sensor

Power Supply

24VAC/VDC (power adaptor selectable)

Power Consumption

2.8W

Response Time

<50s @T90

Signal Update

1s

Warm up Time

<60 seconds

Ozone Measuring Range

0~5000ppb (0-5ppm)( 0~9.81mg/m3)

Display Resolution

1ppb (0.001ppm) (0.01mg/ m3)

Accuracy

+-0.01ppm + 10% reading

Nonlinear

<1%FS

Repeatability

<0.5%

Zero Drift

<1%

Alarm

Buzzer and Yellow or Red backlight switch

Display

Green-normally, yellow – first stage alarm, red- second stage alarm.

Ozone alarm points can be preset.

Temperature/humidity Measuring Range

-20°C~50°C (-4°F~122°F)/5~99%RH

Analog Output

0,2~10VDC or 4~20mA linearized output selectable

Analog Output Resolution

16Bit

Relay dry contact Output

Two dry-contact outputs

Max, switching current 3A (220VAC/30VDC), resistance Load

Communication Interface

RS-485, 9600,14400,19200(default), 28800,38400 bps selectable,

15KV antistatic protection

Working Condition

-20°C~45°C (-4°F~113°F)/ 0~ 95% RH

Storage Conditions

-40°C~70°C (-40°F~158°F)/ 0~ 95% RH 

Net Weight

190g    

Dimensions

130mm(H)×85mm(W)×36.5mm(D)                 

Installation Standard

65mm×65mm or 85mmx85mm or 2”×4” wire box

Interface Connection (Max)

9 terminals

Wiring Standard

Wire section area<1.5mm2

Manufacturing Process

ISO 9001 Certified

Housing and IP class

PC/ABS fireproof plastic material, protection class: IP30

Compliance

EMC Directive 89/336/EEC

 

 

 

1.Design for real time detecting and monitoring ambiance ozone level and temperature

2.Electrochemical ozone sensor with high sensitivity

3.Particular LCD display with three color backlights (Green/Yellow/Red)

4.Maximum ozone measuring range:0~5ppm (0~9.81mg/m3) Also reset the measurement range by end user

5.2xOn/Off dry contact outputs for two stages alarm device, or control a ozone generator or a ventilator

6.Buzzer alarm and 3-color backlight LCD indication

7.Provide 1X analog output (0,2~10VDC/4~20mA)(can be used as transmitter)

8.Modbus RS485 communication interface, 15 KV antistatic protection, individual IP address

9..Provide two easy ways for calibration and setup alarm points via an infrared remote controller or via the RS485 interface.

10.Temperature measurement and display

11.Humidity measurement and display optional

12.Multiple application, wall mounting type and desktop type

13.Great performance with high quality and low price

 

 